Laboratory & Medical Freezers

TEFCOLD SE10-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€84169inc VAT
€69561 excl VAT
TEFCOLD SE20-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€95998inc VAT
€79337 excl VAT
TEFCOLD SE30-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€1,02834inc VAT
€84987 excl VAT
TEFCOLD SE40-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€1,07663inc VAT
€88978 excl VAT
Laboratory & Medical Freezers

Laboratory and medical freezers down to −45 °C - how to choose

This category contains four TEFCOLD SE-series horizontal freezers: SE10-45, SE20-45, SE30-45 and SE40-45. On the current TEFCOLD product pages all four are positioned as “Medical Freezer”. Their stated temperature range is −45 to −5 °C. The first selection question is therefore whether this range matches the actual laboratory, medical or other controlled-storage process - only then should capacity and footprint be compared.

All four models use an electronic thermostat with alarm, a lockable solid lid, static cooling, manual defrost, powder-coated steel interior, one white wire basket and castors with two brakes. The refrigerant is R290. The main differences are net volume, width, input power and energy consumption, from the 152 l SE10-45 up to the 392 l SE40-45.

These units should not be described on this website as ordinary retail or food-display freezers. Although the cabinet format is a horizontal chest, the product family is listed here under laboratory freezers and is currently labelled by TEFCOLD as Medical Freezer. For regulated storage, always verify the exact temperature, monitoring, validation, alarm and backup-power requirements of the stored material against the documentation for the selected model.

Quick model comparison

Model

Net volume

External W×D×H

Energy use

Typical selection logic

SE10-45

152 l

734 × 705 × 945 mm

3.45 kWh/24 h

Most compact option where floor space is limited

SE20-45

230 l

984 × 705 × 945 mm

3.55 kWh/24 h

Medium storage capacity

SE30-45

323 l

1284 × 705 × 945 mm

5.15 kWh/24 h

Higher capacity for larger stored quantities

SE40-45

392 l

1504 × 705 × 945 mm

5.52 kWh/24 h

Largest active SE model in this category

 

 

1. Temperature range: −45 to −5 °C

All four active SE models carry the same stated temperature range of −45 to −5 °C. Within this series, model choice is therefore mainly about capacity and physical size, while the setpoint must follow the requirements of the material being stored.

If your process requires temperatures below −45 °C, the SE range is not suitable. A temperature setting alone also does not prove compliance with a specific medical or laboratory standard.

2. SE10-45 - compact 152 l net model

SE10-45 provides 155 / 152 l gross / net volume and measures 734 × 705 × 945 mm. TEFCOLD lists 3.45 kWh/24 h energy use and 250 W input power.

It is the logical choice where the stored quantity is small and floor space is limited.

3. SE20-45 - 230 l net

SE20-45 provides 235 / 230 l gross / net volume, measures 984 × 705 × 945 mm, uses 3.55 kWh/24 h and has 300 W input power.

It is the mid-size step between the compact SE10-45 and the higher-capacity SE30-45 / SE40-45.

4. SE30-45 - 323 l net

SE30-45 provides 330 / 323 l gross / net volume, measures 1284 × 705 × 945 mm, uses 5.15 kWh/24 h and has 500 W input power.

Choose it when substantially more storage volume is needed but the 1.5 m wide SE40-45 would be unnecessarily large.

5. SE40-45 - largest active model at 392 l net

SE40-45 is the largest active model in the category: 400 / 392 l gross / net volume, 1504 × 705 × 945 mm, 5.52 kWh/24 h energy use and 600 W input power.

Check not only the floor footprint but also lid-opening space and comfortable access across the full 1.5 m cabinet width.

6. Electronic thermostat with alarm

TEFCOLD specifies an electronic thermostat with alarm on all four models. This allows the operating temperature to be set electronically and provides the controller’s alarm function.

Do not infer functions that are not stated on the current product pages, such as cloud monitoring, GSM alarms or integrated continuous data logging.

7. Static cooling

The SE range uses static cooling, with no internal fan-driven air circulation listed. Loading pattern and container placement can therefore influence temperature distribution inside the chest.

If your process requires documented temperature-uniformity performance throughout the entire storage volume, check the relevant manufacturer or validation documentation rather than relying only on the overall temperature range.

8. Manual defrost

All four models use manual defrost. This keeps the refrigeration design simple but requires planned defrosting and an internal procedure for protecting or transferring stored materials during the defrost period.

Defrost frequency will depend on ambient humidity, lid-opening frequency and operating conditions.

9. Solid lockable lid

Each SE model has one hinged solid lid and a lock. The solid construction avoids the additional heat gain of a glass display lid, while the lock provides basic physical access control.

The mechanical lock is not the same as audited electronic access control; where traceability is required, a separate solution may be necessary.

10. Interior, basket and mobility

TEFCOLD specifies a powder-coated steel interior, one white wire basket and four castors, two with brakes. The basket can keep frequently accessed smaller items separate from the main storage volume.

Plan the actual container or box sizes before purchase because the ergonomics of a horizontal chest are very different from an upright laboratory cabinet.

11. Climate class and room conditions

TEFCOLD lists climate class 3 for all four models. This should be considered together with the installation-room conditions and the instructions for the individual model.

Avoid strong external heat sources and leave the ventilation / service clearances required by the manufacturer.

12. R290 refrigerant

SE10-45, SE20-45, SE30-45 and SE40-45 use R290 refrigerant.

R290 is flammable, so refrigeration-system service or leak-related work should be performed by qualified personnel in accordance with the manufacturer instructions and applicable safety requirements.

13. Why the website copy should not focus on food or retail

The current Lithuanian product descriptions incorrectly talk about frozen food, display use, retail and food-service businesses. The current TEFCOLD pages instead position these products as Medical Freezers.

The category and product copy should therefore focus on the −45 to −5 °C range, medical / laboratory positioning, controller with alarm, usable volume and construction - not food merchandising.

14. When the SE range is not enough

The SE range has a clearly defined feature set: −45 to −5 °C, electronic thermostat with alarm, static cooling and manual defrost. It is not a universal solution for every medical application.

If the project requires lower temperatures, continuous data logging, remote alarm, validated temperature uniformity, specific certification or integrated backup systems, verify those requirements separately before selecting an SE model.

Quick selection logic

  • Minimum footprint and around 150 l net capacity - SE10-45.
  • When 152 l is too small but more than 300 l is unnecessary - SE20-45 (230 l net).
  • Higher capacity - SE30-45 (323 l net).
  • Maximum capacity in the active SE range - SE40-45 (392 l net).
  • If the application requires temperatures below −45 °C or specialised monitoring / validation functions, evaluate another equipment class rather than simply choosing a larger SE cabinet.

Frequently asked questions - EN

What is the temperature range of the SE series?

All four active models are specified at −45 to −5 °C.

What is the main difference between SE10-45, SE20-45, SE30-45 and SE40-45?

Main differences are net volume, cabinet width, input power and energy use. The general temperature and feature concept remains the same.

Which is the smallest model?

SE10-45: 152 l net and 734 mm wide.

Which is the largest model?

SE40-45: 392 l net and 1504 mm wide.

Do the units have a temperature alarm?

TEFCOLD specifies an electronic thermostat with alarm on all four models.

Do they have a lock?

Yes. The current product specifications list a lock and one hinged solid lid.

Is the cooling fan-assisted?

No. TEFCOLD specifies static cooling.

Is defrost automatic?

No. The SE series uses manual defrost.

Is a basket included?

Yes. Each model is specified with one white wire basket.

Are the freezers mobile?

They have four castors, two with brakes.

Which refrigerant is used?

All four active SE models use R290.

Can I assume an SE freezer is suitable for any vaccine or medicine?

No. Suitability depends on the exact storage, monitoring and validation requirements of the material and the documentation for the selected model.

Are these intended as food-display freezers on this website?

No. The current TEFCOLD product pages call them Medical Freezers, so this category should not be written as retail food-merchandising equipment.

Does SE40-45 reach a lower temperature than SE10-45?

No. Both have the same −45 to −5 °C range; SE40-45 mainly provides more storage volume.