Laboratory freezers down to −40 / −45 °C

Compact −40 to −30 °C laboratory freezer with two shelves, AISI 304 stainless steel interior and BOL..
€2,62967inc VAT
€2,17328 excl VAT
Upright −45 to −30 °C laboratory freezer with four fixed shelves, AISI 304 interior and BOL50 refrig..
€4,25615inc VAT
€3,51748 excl VAT
Largest listed SLMB model, −45 to −30 °C, four fixed shelves and a 740 mm wide cabinet...
€4,38592inc VAT
€3,62473 excl VAT
TEFCOLD SE10-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€88845inc VAT
€73426 excl VAT
TEFCOLD SE20-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€1,01645inc VAT
€84004 excl VAT
TEFCOLD SE30-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€1,12182inc VAT
€92713 excl VAT
TEFCOLD SE40-45 – medical Freezer. Key specifications: R290. Designed for low-temperature storage; s..
€1,17451inc VAT
€97067 excl VAT

Laboratory freezers down to −40 / −45 °C

This group covers frozen storage of samples, reagents and other materials subject to their storage requirements. The current catalogue includes four TEFCOLD SE chest freezers (−45 to −5 °C). Match the entire operating range, usable capacity and monitoring needs.

Upright BOLARUS SLMB or TEFCOLD SE chest freezer?

The range is being expanded with three upright BOLARUS SLMB models. Compact SLMB 100 operates from −40 to −30 °C and full-height SLMB 500 and 700 from −45 to −30 °C; listed capacities are 100, 500 and 700 l, with net volume to be confirmed. SLMB 500/700 feature four fixed shelves and an AISI 304 interior. These cabinets help separate sample groups on shelves where front access is important. TEFCOLD SE chest freezers remain an option where a wider −45 to −5 °C operating range or top loading is required.

SLMB availability and service arrangements are still being confirmed. Before ordering, verify BOL50 refrigerant service support, the exact defrost method and any additional logging configuration. SLMB 100 does not cover −45 °C; select a model whose entire operating range meets the requirement.

Quick TEFCOLD SE model comparison

Model

Net volume

External W×D×H

Energy use

Typical selection logic

SE10-45

152 l

734 × 705 × 945 mm

3.45 kWh/24 h

Most compact option where floor space is limited

SE20-45

230 l

984 × 705 × 945 mm

3.55 kWh/24 h

Medium storage capacity

SE30-45

323 l

1284 × 705 × 945 mm

5.15 kWh/24 h

Higher capacity for larger stored quantities

SE40-45

392 l

1504 × 705 × 945 mm

5.52 kWh/24 h

Largest active SE model in this category

 

 

1. Temperature range: −45 to −5 °C

All four active SE models carry the same stated temperature range of −45 to −5 °C. Within this series, model choice is therefore mainly about capacity and physical size, while the setpoint must follow the requirements of the material being stored.

If your process requires temperatures below −45 °C, the SE range is not suitable. A temperature setting alone also does not prove compliance with a specific medical or laboratory standard.

2. SE10-45 - compact 152 l net model

SE10-45 provides 155 / 152 l gross / net volume and measures 734 × 705 × 945 mm. TEFCOLD lists 3.45 kWh/24 h energy use and 250 W input power.

It is the logical choice where the stored quantity is small and floor space is limited.

3. SE20-45 - 230 l net

SE20-45 provides 235 / 230 l gross / net volume, measures 984 × 705 × 945 mm, uses 3.55 kWh/24 h and has 300 W input power.

It is the mid-size step between the compact SE10-45 and the higher-capacity SE30-45 / SE40-45.

4. SE30-45 - 323 l net

SE30-45 provides 330 / 323 l gross / net volume, measures 1284 × 705 × 945 mm, uses 5.15 kWh/24 h and has 500 W input power.

Choose it when substantially more storage volume is needed but the 1.5 m wide SE40-45 would be unnecessarily large.

5. SE40-45 - largest TEFCOLD SE model at 392 l net

SE40-45 is the largest active SE model in the category: 400 / 392 l gross / net volume, 1504 × 705 × 945 mm, 5.52 kWh/24 h energy use and 600 W input power.

Check not only the floor footprint but also lid-opening space and comfortable access across the full 1.5 m cabinet width.

6. Electronic thermostat with alarm

TEFCOLD specifies an electronic thermostat with alarm on all four models. This allows the operating temperature to be set electronically and provides the controller’s alarm function.

Do not infer functions that are not stated on the current product pages, such as cloud monitoring, GSM alarms or integrated continuous data logging.

7. Static cooling

The SE range uses static cooling, with no internal fan-driven air circulation listed. Loading pattern and container placement can therefore influence temperature distribution inside the chest.

If your process requires documented temperature-uniformity performance throughout the entire storage volume, check the relevant manufacturer or validation documentation rather than relying only on the overall temperature range.

8. Manual defrost

All four models use manual defrost. This keeps the refrigeration design simple but requires planned defrosting and an internal procedure for protecting or transferring stored materials during the defrost period.

Defrost frequency will depend on ambient humidity, lid-opening frequency and operating conditions.

9. Solid lockable lid

Each SE model has one hinged solid lid and a lock. The solid construction avoids the additional heat gain of a glass display lid, while the lock provides basic physical access control.

The mechanical lock is not the same as audited electronic access control; where traceability is required, a separate solution may be necessary.

10. Interior, basket and mobility

TEFCOLD specifies a powder-coated steel interior, one white wire basket and four castors, two with brakes. The basket can keep frequently accessed smaller items separate from the main storage volume.

Plan the actual container or box sizes before purchase because the ergonomics of a horizontal chest are very different from an upright laboratory cabinet.

11. Climate class and room conditions

TEFCOLD lists climate class 3 for all four models. This should be considered together with the installation-room conditions and the instructions for the individual model.

Avoid strong external heat sources and leave the ventilation / service clearances required by the manufacturer.

12. R290 refrigerant

SE10-45, SE20-45, SE30-45 and SE40-45 use R290 refrigerant.

R290 is flammable, so refrigeration-system service or leak-related work should be performed by qualified personnel in accordance with the manufacturer instructions and applicable safety requirements.

13. Selecting for controlled storage

Select equipment according to the actual material, temperature and monitoring requirements. A temperature range alone does not establish suitability for every medicine, vaccine or laboratory sample. Where required, confirm the selected model’s temperature uniformity, logging and validation documentation before purchase.

14. When the SE range is not enough

The SE range has a clearly defined feature set: −45 to −5 °C, electronic thermostat with alarm, static cooling and manual defrost. It is not a universal solution for every medical application.

If the project requires lower temperatures, continuous data logging, remote alarm, validated temperature uniformity, specific certification or integrated backup systems, verify those requirements separately before selecting an SE model.

Quick selection logic

  • Minimum footprint and around 150 l net capacity - SE10-45.
  • When 152 l is too small but more than 300 l is unnecessary - SE20-45 (230 l net).
  • Higher capacity - SE30-45 (323 l net).
  • Maximum capacity in the active SE range - SE40-45 (392 l net).
  • If the application requires temperatures below −45 °C or specialised monitoring / validation functions, evaluate another equipment class rather than simply choosing a larger SE cabinet.

Frequently asked questions

1. What is the temperature range of the SE series?

All four active models are specified at −45 to −5 °C.

2. What is the main difference between SE10-45, SE20-45, SE30-45 and SE40-45?

Main differences are net volume, cabinet width, input power and energy use. The general temperature and feature concept remains the same.

3. Which TEFCOLD SE model is the smallest?

SE10-45: 152 l net and 734 mm wide.

4. Which TEFCOLD SE model is the largest?

SE40-45: 392 l net and 1504 mm wide.

5. TEFCOLD SE: Do the units have a temperature alarm?

TEFCOLD specifies an electronic thermostat with alarm on all four models.

6. TEFCOLD SE: Do they have a lock?

Yes. The current product specifications list a lock and one hinged solid lid.

7. TEFCOLD SE: Is the cooling fan-assisted?

No. TEFCOLD specifies static cooling.

8. TEFCOLD SE: Is defrost automatic?

No. The SE series uses manual defrost.

9. TEFCOLD SE: Is a basket included?

Yes. Each model is specified with one white wire basket.

10. TEFCOLD SE: Are the freezers mobile?

They have four castors, two with brakes.

11. TEFCOLD SE: Which refrigerant is used?

All four active SE models use R290.

12. Can I assume an SE freezer is suitable for any vaccine or medicine?

No. Suitability depends on the exact storage, monitoring and validation requirements of the material and the documentation for the selected model.

14. Does SE40-45 reach a lower temperature than SE10-45?

No. Both have the same −45 to −5 °C range; SE40-45 mainly provides more storage volume.