CALKLIN 200 supplies five separately packed 200 g portions for scheduled ice-machine descaling.
CALKLIN removes scale and mineral deposits from the water circuit. Deposits can restrict flow and heat transfer. Filtration reduces some causes of contamination or scaling but does not eliminate cleaning requirements.
Plan maintenance and an assessment of cleaning needs at least every six months. ITV's NG R290 instructions require at least six-monthly inspection and cleaning. Follow the exact procedure for other models. Hard water or faster deposit formation requires earlier descaling.
An annual interval in older documents is not universal guidance for every machine. Daily bin, scoop and ice-contact hygiene is separate.
The manufacturer's DELTA / ORION / ICE QUEEN CALKLIN method specifies 50 g per litre of water. Apply this where the procedure calls for it; newer exact-model instructions and the chemical label take precedence.
Examples at that concentration: 1 litre of water needs 50 g; 2 litres 100 g; 4 litres 200 g. One 200 g sachet corresponds mathematically to 4 litres of water at this ratio, not automatically to one cleaning.
Calculate grams required = specified g/l concentration × litres of water needed by the procedure. Where several fresh fills are required, include all of them. Daily ice output alone does not determine cleaning-circuit volume.
If the manual does not state the amount, provide the exact model and serial number to service personnel. For IQF and SCALA, select the dose from the exact circuit and cleaning instructions rather than daily output alone.
IQN / IQF: the 2026 instructions specify 10 litres of solution: 5 for hand washing and 5 for the circuit. They name ScaleKleen; service personnel must confirm CALKLIN substitution and concentration. Do not automatically apply 50 g/l. Check your equipment version.
SCALA: circuit-cleaning guidance is six months for hard water or twelve in normal conditions. General hygiene maintenance is separate; determine the CALKLIN quantity for the exact installation.
Controls differ by model and version. Qualified service personnel carry out dismantling or internal electrical work. Use label-specified protection and do not mix CALKLIN with chlorine-based or other cleaners.
No. Descaling and sanitising have different functions. Where specified, sanitise separately after appropriate rinsing using a compatible food-equipment product and procedure.
Pack details remain in Specification. See the accessories guide for maintenance and filter selection.
| Technical data | |
|---|---|
| Application sector | Service / maintenance |
| Ice application | Periodic ice-maker descaling and water-circuit cleaning |
| Manufacturer SKU – standard model | 33346 |
There are no reviews for this product!