INTARCON MSH-NN-22018A split refrigeration system with low-profile evaporator

Product code: MSH-NN-22018A

Available quantity 4-6 weeks

INTARCON MSH-NN-22018A: standard cold rooms. Evaporator: Low-profile (slim). Temperature-specific capacity and room-volume ratings are in the specification.
€4,23850 inc VAT
€3,50289 excl VAT
Have any questions about this item? Ask
Manufacturer: INTARCON

A matched split system for product storage

INTARCON MSH-NN-22018A is a split system for standard cold rooms. This system separates the indoor evaporator from the heat-rejecting condensing unit, allowing the cold-room layout and outdoor ventilation/service space to be planned independently. The factory-matched package helps coordinate the refrigeration equipment.

Practical benefits

  • Evaporator suited to room geometry: a low-profile unit preserves ceiling space; a cubic evaporator should be assessed where directed airflow is needed through a longer or more heavily loaded room. Leave circulation and service clearances.
  • Separate heat rejection: allows the condensing unit to be positioned outside the room. Its location must admit fresh air and remove the heat discharged by the refrigeration circuit.
  • Factory refrigeration components: include thermostatic expansion and solenoid valves, pressure protection and electronic control. Site pipework and installation are planned separately.

This model uses a low-profile (slim) evaporator. Use the temperature-specific ratings in the specification when sizing the room.

Construction designed for servicing

Removable grilles provide access to the fan and coil; Sigilus fan quick connectors simplify removal. The electrical panel has separate access from the refrigeration compartment. Side pipe connections and an accessible safety valve support installation and maintenance. The illustration shows the range construction. R455A is an A2L refrigerant. Assess installation location, permissible charge and room conditions using the exact model instructions. Factory pre-charge covers up to 10 m; longer runs require the manufacturer line-sizing and additional refrigerant/POE oil table.

View the construction illustration
INTARCON A2L maintenance design features

Range configuration and selection limits

Select freezer equipment at the required negative-temperature point and positive-temperature equipment at its actual room setpoint. The catalogue volume is an initial selection estimate. Frequent door openings and warm incoming stock can require more capacity in a room of the same volume.

Condensing unit location and installation

An axial-fan unit needs unobstructed air intake and discharge. Avoid an enclosed, unventilated recess. Where ducted heat rejection is necessary, select a suitable centrifugal configuration and check its own technical ratings.

The manufacturer specifies a maximum vertical separation of 15 m with the condensing unit above the evaporator, or 6 m with it below. These are elevation limits, not pre-charge pipe lengths. Provide a trapped, sloping condensate drain and follow the installation drawing for refrigerant piping and oil return.

How to size this model

Published capacity points for this factory model: 0, +5, +10 °C. In the specification, compare capacity and estimated room volume at the same room temperature. Cooling capacity is not electrical input. Provide internal room dimensions, insulation, ambient temperature, daily product load and incoming temperature, door-opening frequency and the proposed pipe route. An unpublished operating point must not be substituted by a rating at a different temperature.

Dimension drawing

MSH-NN-22018A condensing unit and evaporator dimensions
Manufacturer range drawing. MSH-NN-22018A size row: 22. Condensing unit (W×D×H): 598 × 902 × 485 mm; evaporator: 993 × 430 × 235 mm.

Unit interconnection principle

MSH-NN-22018A installation diagram
Manufacturer principle diagram showing liquid and gas piping, electrical interconnection, control pad and condensate drainage. Unit appearance is illustrative; follow the selected model instructions for pipe sizing and safety requirements.

Supply scope and documentation

Supply covers the factory condensing unit, evaporator and range-specific controls. The cold-room enclosure, site copper pipework and insulation, electrical installation and commissioning are planned separately. Pre-charge for 10 m does not itself mean that pipes or all interconnecting cables are supplied.

Manufacturer catalogue, printed p. 299. Range and filter selection guide.

Capacity and internal fittings
Recommended cold-room volume at +0 °C, m³ 16
Recommended cold-room volume at +10 °C, m³ 47
Recommended cold-room volume at +5 °C, m³ 28
Dimensions and weight
Condensing unit depth, mm 902
Condensing unit dimensions (W×D×H), mm 598 × 902 × 485
Condensing unit height, mm 485
Condensing unit width, mm 598
Evaporator depth, mm 430
Evaporator dimensions (W×D×H), mm 993 × 430 × 235
Evaporator height, mm 235
Evaporator width, mm 993
Weight, kg 83
Energy and electrical data
Voltage / Frequency, V/Hz 230V I+N ~ 50Hz
General information
Delivery method Made to order; lead time on request
Equipment type Refrigeration system
Purpose Standard cold rooms
Series MSH-NN
Refrigeration and ventilation system
Complete split kit scope Condensing unit + evaporator + series controls and refrigeration components
Condenser / evaporator elevation limits 15 m with condenser above evaporator; 6 m with condenser below
Evaporator type Low-profile (slim)
Factory refrigerant pre-charge pipe length, m 10
Noise Level, dB(A) 40 (10 m)
Refrigerant R455A
Refrigeration system type Split system
Temperature and performance
Cooling capacity at +0 °C, W 1562
Cooling capacity at +10 °C, W 2268
Cooling capacity at +5 °C, W 1909
Temperature group Positive temperature