INTARCON MSF-UG-1038A: unpacked meat preservation. Evaporator: Quasi-static, double-flow. Temperature-specific capacity and room-volume ratings are in the specification.
€6,82888 inc VAT
€5,64370 excl VAT
Have any questions about this item? Ask
Manufacturer: INTARCON

Unpacked meat preservation and optional maturation

INTARCON MSF-UG-1038A is a split system for unpacked meat preservation. This range is designed for unpacked meat storage in cold rooms around 0 °C. Its quasi-static evaporator uses very low-speed fans and distributes air in two directions, producing movement similar to natural convection. Gentle circulation helps limit direct exposure and moisture loss from the product surface.

Practical benefits

  • Gentle double-flow circulation: helps reduce surface drying. Leave both discharge paths and the return-air path unobstructed when planning rails, racks and hanging products.
  • Separate heat rejection: allows the condensing unit to be positioned outside the cold room and serviced without clearing the storage space.
  • Electronic control and electric defrost: manage room temperature and frost removal. The factory refrigeration circuit includes solenoid and thermostatic expansion valves and high/low pressure protection.

Range configuration and selection limits

Meat preservation and maturation need different configurations. The manufacturer offers optional maturation control with humidification and dehumidification, a VTIPG touch display and a steam humidifier rated up to 3 kg/h. That configuration is intended for rooms around 0 °C with a 40–95 % relative humidity control range. It is ordered separately and is not a standard preservation feature.

Condensing unit location and installation

An axial-fan unit needs unobstructed air intake and discharge. Avoid an enclosed, unventilated recess. Where ducted heat rejection is necessary, select a suitable centrifugal configuration and check its own technical ratings.

The manufacturer specifies a maximum vertical separation of 15 m with the condensing unit above the evaporator, or 6 m with it below. These are elevation limits, not pre-charge pipe lengths. Provide a trapped, sloping condensate drain and follow the installation drawing for refrigerant piping and oil return.

How to size this model

Published capacity points for this factory model: −5, 0, +5, +10 °C. In the specification, compare capacity and estimated room volume at the same room temperature. Cooling capacity is not electrical input. Provide internal room dimensions, insulation, ambient temperature, daily product load and incoming temperature, door-opening frequency and the proposed pipe route. An unpublished operating point must not be substituted by a rating at a different temperature.

Dimension drawing

MSF-UG-1038A condensing unit and evaporator dimensions
Manufacturer range drawing. MSF-UG-1038A size row: 13. Condensing unit (W×D×H): 1030 × 380 × 577 mm; evaporator: 1786 × 798 × 312 mm.

Unit interconnection principle

MSF-UG-1038A installation diagram
Manufacturer principle diagram showing liquid and gas piping, electrical interconnection, control pad and condensate drainage. Unit appearance is illustrative; follow the selected model instructions for pipe sizing and safety requirements.

Supply scope and documentation

Supply covers the factory condensing unit, evaporator and range-specific controls. The cold-room enclosure, site copper pipework and insulation, electrical installation and commissioning are planned separately. Pre-charge for 10 m does not itself mean that pipes or all interconnecting cables are supplied.

Manufacturer catalogue, printed p. 313. Range and filter selection guide.

Capacity and internal fittings
Recommended cold room volume at −5 °C, m³ 31
Recommended cold-room volume at +0 °C, m³ 47
Recommended cold-room volume at +10 °C, m³ 115
Recommended cold-room volume at +5 °C, m³ 72
Dimensions and weight
Condensing unit depth, mm 380
Condensing unit dimensions (W×D×H), mm 1030 × 380 × 577
Condensing unit height, mm 577
Condensing unit width, mm 1030
Evaporator depth, mm 798
Evaporator dimensions (W×D×H), mm 1786 × 798 × 312
Evaporator height, mm 312
Evaporator width, mm 1786
Weight, kg 145
Energy and electrical data
Voltage / Frequency, V/Hz 400V 3N ~ 50Hz
General information
Delivery method Made to order; lead time on request
Equipment type Refrigeration system
Purpose Unpacked meat preservation
Series MSF-UG
Refrigeration and ventilation system
Complete split kit scope Condensing unit + evaporator + series controls and refrigeration components
Condenser / evaporator elevation limits 15 m with condenser above evaporator; 6 m with condenser below
Evaporator type Quasi-static, double-flow
Factory refrigerant pre-charge pipe length, m 10
Noise Level, dB(A) 29 (10 m)
Refrigerant R449A
Refrigeration system type Split system
Relative humidity, % 40–95 % only with optional maturation configuration
Temperature and performance
Cooling capacity at +0 °C, W 3451
Cooling capacity at +10 °C, W 4882
Cooling capacity at +5 °C, W 4130
Cooling capacity at −5 °C, W 2833
Temperature group Positive temperature