INTARCON MSF-QY-33171A split refrigeration system with cubic evaporator

Product code: MSF-QY-33171A

Available quantity 4-6 weeks

INTARCON MSF-QY-33171A: standard cold rooms. Evaporator: Cubic. Temperature-specific capacity and room-volume ratings are in the specification.
€11,29011 inc VAT
€9,33067 excl VAT
Have any questions about this item? Ask
Manufacturer: INTARCON

A matched split system for product storage

INTARCON MSF-QY-33171A is a split system for standard cold rooms. This system separates the indoor evaporator from the heat-rejecting condensing unit, allowing the cold-room layout and outdoor ventilation/service space to be planned independently. The factory-matched package helps coordinate the refrigeration equipment.

Practical benefits

  • Evaporator suited to room geometry: a low-profile unit preserves ceiling space; a cubic evaporator should be assessed where directed airflow is needed through a longer or more heavily loaded room. Leave circulation and service clearances.
  • Separate heat rejection: allows the condensing unit to be positioned outside the room. Its location must admit fresh air and remove the heat discharged by the refrigeration circuit.
  • Factory refrigeration components: include thermostatic expansion and solenoid valves, pressure protection and electronic control. Site pipework and installation are planned separately.

This model uses a cubic evaporator. Use the temperature-specific ratings in the specification when sizing the room.

Range configuration and selection limits

Select freezer equipment at the required negative-temperature point and positive-temperature equipment at its actual room setpoint. The catalogue volume is an initial selection estimate. Frequent door openings and warm incoming stock can require more capacity in a room of the same volume.

The low-noise Sigilus design combines an insulated compressor compartment, lower-speed fans and vibration isolation. The catalogue specifies the compressor sound jacket for standard three-phase Danfoss compressors; it must not automatically be assumed for every single-phase model. Removable panels provide service access.

The remote XM670K controller has a clock for defrost scheduling and minimum/maximum temperature recording. The range supports synchronisation of up to 8 compatible units over a local network; site wiring and interconnections are planned separately.

Condensing unit location and installation

An axial-fan unit needs unobstructed air intake and discharge. Avoid an enclosed, unventilated recess. Where ducted heat rejection is necessary, select a suitable centrifugal configuration and check its own technical ratings.

The manufacturer specifies a maximum vertical separation of 15 m with the condensing unit above the evaporator, or 6 m with it below. These are elevation limits, not pre-charge pipe lengths. Provide a trapped, sloping condensate drain and follow the installation drawing for refrigerant piping and oil return.

How to size this model

Published capacity points for this factory model: −5, 0, +5, +10 °C. In the specification, compare capacity and estimated room volume at the same room temperature. Cooling capacity is not electrical input. Provide internal room dimensions, insulation, ambient temperature, daily product load and incoming temperature, door-opening frequency and the proposed pipe route. An unpublished operating point must not be substituted by a rating at a different temperature.

Dimension drawing

MSF-QY-33171A condensing unit and evaporator dimensions
Manufacturer range drawing. MSF-QY-33171A size row: 33. Condensing unit (W×D×H): 1150 × 487 × 1097 mm; evaporator: 1930 × 455 × 581 mm.

Unit interconnection principle

MSF-QY-33171A installation diagram
Manufacturer principle diagram showing liquid and gas piping, electrical interconnection, control pad and condensate drainage. Unit appearance is illustrative; follow the selected model instructions for pipe sizing and safety requirements.

Supply scope and documentation

Supply covers the factory condensing unit, evaporator and range-specific controls. The cold-room enclosure, site copper pipework and insulation, electrical installation and commissioning are planned separately. Pre-charge for 10 m does not itself mean that pipes or all interconnecting cables are supplied.

Manufacturer catalogue, printed p. 308. Range and filter selection guide.

Capacity and internal fittings
Recommended cold room volume at −5 °C, m³ 100
Recommended cold-room volume at +0 °C, m³ 172
Recommended cold-room volume at +10 °C, m³ 354
Recommended cold-room volume at +5 °C, m³ 197
Dimensions and weight
Condensing unit depth, mm 487
Condensing unit dimensions (W×D×H), mm 1150 × 487 × 1097
Condensing unit height, mm 1097
Condensing unit width, mm 1150
Evaporator depth, mm 455
Evaporator dimensions (W×D×H), mm 1930 × 455 × 581
Evaporator height, mm 581
Evaporator width, mm 1930
Weight, kg 229
Energy and electrical data
Voltage / Frequency, V/Hz 400V 3N ~ 50Hz
General information
Delivery method Made to order; lead time on request
Equipment type Refrigeration system
Purpose Standard cold rooms
Series MSF-QY
Refrigeration and ventilation system
Complete split kit scope Condensing unit + evaporator + series controls and refrigeration components
Condenser / evaporator elevation limits 15 m with condenser above evaporator; 6 m with condenser below
Evaporator type Cubic
Factory refrigerant pre-charge pipe length, m 10
Noise Level, dB(A) 40 (10 m)
Refrigerant R134a
Refrigeration system type Split system
Temperature and performance
Cooling capacity at +0 °C, W 8484
Cooling capacity at +10 °C, W 12306
Cooling capacity at +5 °C, W 10295
Cooling capacity at −5 °C, W 6746
Temperature group Positive temperature