INTARCON MCR-NN-2024A roof-mounted R455A A2L monoblock, 1850 W

Product code: MCR-NN-2024A

Available quantity 4-6 weeks

INTARTOP A2L CR-NN MCR-NN-2024A, roof-mounted A2L unit for positive-temperature rooms, 1850 W at +0 °C, up to 20 m³ (+35 °C ambient). XW270K; made to order.
€3,68566 inc VAT
€3,04600 excl VAT
Have any questions about this item? Ask
Manufacturer: INTARCON

INTARCON INTARTOP A2L CR-NN MCR-NN-2024A – a roof-mounted refrigeration monoblock for a positive-temperature cold room. Refrigerant R455A is A2L class, global warming potential (GWP) 146. Select by actual heat load, temperature and volume.

Cooling capacity and recommended room size

Room temperatureCooling capacityVolume
0 °C1850 W20 m³
+5 °C2210 W34 m³
+10 °C2592 W56 m³

Manufacturer data at +35 °C ambient. Room volumes are indicative and do not substitute for a heat-load assessment.

Standard equipment

R455A (A2L) refrigerant, hermetic reciprocating compressor, high-pressure safety switch, thermostatic expansion valve, circuit-breaker protection, hot-gas defrost, condensate management and automatic evaporation, LED cold-room lighting and door micro-switch connection cable. Optional accessory hardware is selected separately.

XW270K controller with remote digital control, min/max temperature recording, Jet Cool and night mode.

Mounting and dimensions

Roof installation using the A–I panel drawing; verify exact cut-out and panel thickness against the specific manufacturer's installation instructions. Manufacturer size 2, catalog supply 230V I+N ~ 50Hz. Lettered A–I dimensions refer to the 2026 manufacturer catalog p. 289 installation drawing.

ReferenceDimension
A835 mm
B756 mm
C677 mm
D850 mm
E379 mm
F469 mm
G135 mm
H760 mm
I385 mm

Condenser exhaust and accessories

The standard axial condenser fan is not suited to ducts. For ducted hot-air exhaust select the centrifugal fan (horizontal or vertical discharge on roof models). Up to 20 m equivalent duct length, with each 90° bend equivalent to 5 m. Check duct section and total resistance. Circular-duct adaptor and damper are separate options.

Optional anti-corrosion coating, voltage protection, door switch and Master–Slave adaptation may be selected subject to compatibility.

Safety and supply

R455A is A2L-class refrigerant; installation and servicing require qualified personnel. The cold room, installation, commissioning and unloading are excluded unless agreed otherwise. Made to order; lead time 4–6 weeks.

Capacity and internal fittings
Capacity Cooling Coldroom Units, m³ 20
Recommended cold-room volume at +0 °C, m³ 20
Recommended cold-room volume at +10 °C, m³ 56
Recommended cold-room volume at +5 °C, m³ 34
Controls and functions
Controller XW270K
Dimensions and weight
Dimensions according to manufacturer drawing A=835; B=756; C=677; D=850; E=379; F=469; G=135; H=760; I=385 mm
Mounting configuration Roof installation using the A–I panel drawing; verify exact cut-out and panel thickness against the specific manufacturer's installation instructions.
Weight, kg 97
Energy and electrical data
Input Power, W 1100
Maximum current draw, A 14.4
Voltage / Frequency, V/Hz 230V I+N ~ 50Hz
General information
Delivery method Made to order; lead time 4–6 weeks
Mounting type Roof-mounted
Series INTARTOP A2L CR-NN
Refrigeration and ventilation system
Condenser cooling Air-cooled
Defrost Type Hot-gas defrost
Evaporator airflow, m³/h 1050
Noise Level, dB(A) 35 (at 10 m)
Refrigerant R455A (A2L)
Refrigerant Charge, g less than 1500
Refrigerant GWP 146
Temperature and performance
Cooling capacity at +0 °C, W 1850
Cooling capacity at +10 °C, W 2592
Cooling capacity at +5 °C, W 2210
Temperature group Positive temperature