• English
  • Lithuanian
excl VAT

INTARCON HSF-DY-13053A split refrigeration system with double-flow evaporator

Product code: HSF-DY-13053A

Available quantity 4-6 weeks

INTARCON HSF-DY-13053A: high relative humidity rooms. Evaporator: Double-flow. Temperature-specific capacity and room-volume ratings are in the specification.
€7,01741 inc VAT
€5,79951 excl VAT
Have any questions about this item? Ask
Manufacturer: INTARCON

High relative humidity storage rooms

INTARCON HSF-DY-13053A is a split system for high relative humidity rooms. An oversized double-flow evaporator and combined temperature/humidity control distinguish this range from ordinary cold-room units. It is intended for positive-temperature applications where excessive product drying is undesirable. Suitability for unpacked products or cheese storage must be assessed against the actual product process.

Practical benefits

  • Passive humidity regulation: adjusts evaporator airflow. The stated 60–95 % control range depends on room conditions, product moisture and outside absolute humidity.
  • Double-flow distribution: delivers air towards both sides of the room. Maintain unobstructed supply and return paths when planning racks.
  • Temperature and humidity display: provides both readings on the remote controller. This range uses air defrost.

Range configuration and selection limits

Passive regulation does not mean the standard unit can actively humidify every room to 95 %. Steam humidification, dehumidification and heating require suitable optional factory kits. State the target humidity, product moisture release and door-opening pattern before selecting the configuration.

Condensing unit location and installation

An axial-fan unit needs unobstructed air intake and discharge. Avoid an enclosed, unventilated recess. Where ducted heat rejection is necessary, select a suitable centrifugal configuration and check its own technical ratings.

The manufacturer specifies a maximum vertical separation of 15 m with the condensing unit above the evaporator, or 6 m with it below. These are elevation limits, not pre-charge pipe lengths. Provide a trapped, sloping condensate drain and follow the installation drawing for refrigerant piping and oil return.

How to size this model

Published capacity points for this factory model: +5, +10 °C. In the specification, compare capacity and estimated room volume at the same room temperature. Cooling capacity is not electrical input. Provide internal room dimensions, insulation, ambient temperature, daily product load and incoming temperature, door-opening frequency and the proposed pipe route. An unpublished operating point must not be substituted by a rating at a different temperature.

Dimension drawing

HSF-DY-13053A condensing unit and evaporator dimensions
Manufacturer range drawing. HSF-DY-13053A size row: 13. Condensing unit (W×D×H): 1030 × 380 × 577 mm; evaporator: 1786 × 798 × 312 mm.

Unit interconnection principle

HSF-DY-13053A installation diagram
Manufacturer principle diagram showing liquid and gas piping, electrical interconnection, control pad and condensate drainage. Unit appearance is illustrative; follow the selected model instructions for pipe sizing and safety requirements.

Supply scope and documentation

Supply covers the factory condensing unit, evaporator and range-specific controls. The cold-room enclosure, site copper pipework and insulation, electrical installation and commissioning are planned separately. Pre-charge for 10 m does not itself mean that pipes or all interconnecting cables are supplied.

Manufacturer catalogue, printed p. 315. Range and filter selection guide.

Capacity and internal fittings
Recommended cold-room volume at +10 °C, m³ 103
Recommended cold-room volume at +5 °C, m³ 64
Dimensions and weight
Condensing unit depth, mm 380
Condensing unit dimensions (W×D×H), mm 1030 × 380 × 577
Condensing unit height, mm 577
Condensing unit width, mm 1030
Evaporator depth, mm 798
Evaporator dimensions (W×D×H), mm 1786 × 798 × 312
Evaporator height, mm 312
Evaporator width, mm 1786
Weight, kg 142
Energy and electrical data
Voltage / Frequency, V/Hz 230V I+N ~ 50Hz
General information
Delivery method Made to order; lead time on request
Equipment type Refrigeration system
Purpose High relative humidity rooms
Series HSF-DY
Refrigeration and ventilation system
Complete split kit scope Condensing unit + evaporator + series controls and refrigeration components
Condenser / evaporator elevation limits 15 m with condenser above evaporator; 6 m with condenser below
Evaporator type Double-flow
Factory refrigerant pre-charge pipe length, m 10
Noise Level, dB(A) 35 (10 m)
Refrigerant R134a
Refrigeration system type Split system
Relative humidity, % 60–95 % (passive control; depends on room and product)
Temperature and performance
Cooling capacity at +10 °C, W 4237
Cooling capacity at +5 °C, W 3486
Temperature group Positive temperature

There are no reviews for this product!