• English
  • Lithuanian
excl VAT

INTARCON BCR-ND-1017A roof-mounted R290 monoblock for freezer cold room, 660 W

Product code: BCR-ND-1017A

Available quantity 4-6 weeks

INTARTOP R290 CR-ND BCR-ND-1017A, roof-mounted R290 monoblock for freezer rooms. 660 W, volume up to 5 m³ at -20 °C room and +35 °C ambient. Made to order.
€3,03664 inc VAT
€2,50962 excl VAT
Have any questions about this item? Ask
Manufacturer: INTARCON

INTARCON INTARTOP R290 CR-ND BCR-ND-1017A is a roof-mounted R290 refrigeration monoblock for freezer cold rooms, intended for small to medium commercial applications. R290 (propane) is an A3 refrigerant, GWP 0.02.

Cooling capacity and recommended room volume

Room temperatureCooling capacityRecommended volume
-25 °C540 W2 m³
-20 °C660 W5 m³
-15 °C800 W8 m³

Ratings are stated at +35 °C ambient. Recommended room volumes are indicative only; verify actual thermal loads including insulation, door use, product loading and ventilation.

Standard equipment and control

Hermetic compressor, high/low pressure switches, thermostatic expansion valve, circuit-breaker protection, hot-gas defrost, stainless-steel drain pan with automatic evaporation, LED cold-room lighting, door micro-switch and 50 mm insulated evaporator housing.

XW270K controller: Remote digital control, max/min temperature recording, Jet Cool and night operation mode.

A door heater cable is specified for the negative-temperature ceiling models.

Mounting and dimensions

Roof-panel installation according to the manufacturer drawing; A–I refer to equipment dimensions. Size series 1. Drawing dimensions must not be treated as verified panel cut-out dimensions. Confirm the exact model's installation drawings in the 2026 manufacturer catalog, printed p. 283.

Drawing letterDimension
A665 mm
B582 mm
C574 mm
D850 mm
E379 mm
F385 mm
G135 mm
H590 mm
I385 mm

Optional factory equipment

Optional epoxy coating of the evaporator coil and polyurethane coating of the condenser coil are separately priced factory upgrades, not part of the standard configuration.

Safety and delivery

R290 is an A3 flammable refrigerant; installation, electrical connection and servicing must be carried out by qualified personnel according to the manufacturer's safety and room ventilation requirements. The cold room, installation, commissioning and unloading are excluded unless otherwise agreed. Made to order; lead time 4–6 weeks.

Capacity and internal fittings
Capacity Cooling Coldroom Units, m³ 5
Recommended cold-room volume at −15 °C, m³ 8
Recommended cold-room volume at −20 °C, m³ 5
Recommended cold-room volume at −25 °C, m³ 2
Controls and functions
Controller XW270K
Dimensions and weight
Dimensions according to manufacturer drawing A=665; B=582; C=574; D=850; E=379; F=385; G=135; H=590; I=385 mm
Mounting configuration Roof-panel installation according to the manufacturer drawing; A–I refer to equipment dimensions.
Weight, kg 73
Energy and electrical data
Input Power, W 490
Maximum current draw, A 3.5
Voltage / Frequency, V/Hz 230 V 1N~ 50 Hz
General information
Delivery method Made to order; lead time 4–6 weeks
Mounting type Roof-mounted
Series INTARTOP R290 CR-ND
Refrigeration and ventilation system
Condenser cooling Air-cooled
Defrost Type Hot-gas defrost
Evaporator airflow, m³/h 600
Noise Level, dB(A) 29 (at 10 m)
Refrigerant R290 (A3)
Refrigerant Charge, g less than 100
Refrigerant GWP 0.02
Temperature and performance
Cooling capacity at −15 °C, W 800
Cooling capacity at −20 °C, W 660
Cooling capacity at −25 °C, W 540
Temperature group Negative temperature

There are no reviews for this product!

Write
Call us