• English
  • Lithuanian
excl VAT

INTARCON ASH-DG-3026A split refrigeration system with double-flow evaporator

Product code: ASH-DG-3026A

Available quantity 4-6 weeks

INTARCON ASH-DG-3026A: cooled working rooms. Evaporator: Double-flow. Temperature-specific capacity and room-volume ratings are in the specification.
€5,18675 inc VAT
€4,28657 excl VAT
Have any questions about this item? Ask
Manufacturer: INTARCON

Cooled food preparation and working rooms

INTARCON ASH-DG-3026A is a split system for cooled working rooms. This higher-temperature range is intended for cooled working rooms. The evaporator supplies air through both sides of its coil. Its fan arrangement promotes smoother circulation with less turbulence, making it a useful choice where people work and direct draughts need to be limited.

Practical benefits

  • Double-flow air supply: serves both sides of the working area. Check air velocity before locating the unit directly above a permanent workstation.
  • Working-room sizing points: are published at +9, +12 and +15 °C. A cold-room capacity measured at 0 °C is not an equivalent comparison.
  • Remote electronic control: allows the room setpoint to be selected and monitored from a convenient location. The controls and refrigeration components form a factory-matched package.
Double-flow evaporator airflow in a working room
The double-flow evaporator supplies air through both sides of the coil. Smoother circulation helps limit turbulence in the working area; actual comfort depends on location, air velocity and workstation layout.

Range configuration and selection limits

Working-room load calculations must include people, lights, process equipment, ventilation and open doors. Room volume alone is insufficient. Provide operating hours and the main sources of heat and moisture before equipment selection.

The remote XM670K controller has a clock for defrost scheduling and minimum/maximum temperature recording. The range supports synchronisation of up to 8 compatible units over a local network; site wiring and interconnections are planned separately.

Condensing unit location and installation

An axial-fan unit needs unobstructed air intake and discharge. Avoid an enclosed, unventilated recess. Where ducted heat rejection is necessary, select a suitable centrifugal configuration and check its own technical ratings.

The manufacturer specifies a maximum vertical separation of 15 m with the condensing unit above the evaporator, or 6 m with it below. These are elevation limits, not pre-charge pipe lengths. Provide a trapped, sloping condensate drain and follow the installation drawing for refrigerant piping and oil return.

How to size this model

Published capacity points for this factory model: +9, +12, +15 °C. In the specification, compare capacity and estimated room volume at the same room temperature. Cooling capacity is not electrical input. Provide internal room dimensions, insulation, ambient temperature, daily product load and incoming temperature, door-opening frequency and the proposed pipe route. An unpublished operating point must not be substituted by a rating at a different temperature.

Other factory configuration available in this card: ASH-CDG-3026A. The selection changes the condensing-unit configuration; use the selected SKU data when comparing equipment.

Dimension drawing

ASH-DG-3026A condensing unit and evaporator dimensions
Manufacturer range drawing. ASH-DG-3026A size row: 33. Condensing unit (W×D×H): 925 × 580 × 515 mm; evaporator: 1086 × 798 × 310 mm.

Unit interconnection principle

ASH-DG-3026A installation diagram
Manufacturer principle diagram showing liquid and gas piping, electrical interconnection, control pad and condensate drainage. Unit appearance is illustrative; follow the selected model instructions for pipe sizing and safety requirements.

Supply scope and documentation

Supply covers the factory condensing unit, evaporator and range-specific controls. The cold-room enclosure, site copper pipework and insulation, electrical installation and commissioning are planned separately. Pre-charge for 10 m does not itself mean that pipes or all interconnecting cables are supplied.

Manufacturer catalogue, printed p. 305. Range and filter selection guide.

Capacity and internal fittings
Recommended cold room volume at +12 °C, m³ 42
Recommended cold room volume at +15 °C, m³ 57
Recommended cold room volume at +9 °C, m³ 33
Dimensions and weight
Condensing unit depth, mm 580
Condensing unit dimensions (W×D×H), mm 925 × 580 × 515
Condensing unit height, mm 515
Condensing unit width, mm 925
Evaporator depth, mm 798
Evaporator dimensions (W×D×H), mm 1086 × 798 × 310
Evaporator height, mm 310
Evaporator width, mm 1086
Weight, kg 119
Energy and electrical data
Voltage / Frequency, V/Hz 230V I+N ~ 50Hz
General information
Delivery method Made to order; lead time on request
Equipment type Refrigeration system
Purpose Cooled working rooms
Series ASH-DG
Refrigeration and ventilation system
Complete split kit scope Condensing unit + evaporator + series controls and refrigeration components
Condenser / evaporator elevation limits 15 m with condenser above evaporator; 6 m with condenser below
Evaporator type Double-flow
Factory refrigerant pre-charge pipe length, m 10
Noise Level, dB(A) 37 (10 m)
Refrigerant R449A
Refrigeration system type Split system
Temperature and performance
Cooling capacity at +12 °C, W 3709
Cooling capacity at +15 °C, W 3996
Cooling capacity at +9 °C, W 3434
Temperature group Positive temperature

There are no reviews for this product!

Write